Includes:
Power supply cable
5.7“ / 144 mm color display
Internal printer
RS232/USB interface for data download
Space for six power-phases and options
Fluke NormaView PC software
User’s manual
Test certificate
Calibration values
General Specifications | ||
Number of Phases | Fluke Norma 4000: | 1 to 3 |
Fluke Norma 5000: | 3, 4 or 6 | |
On-board Printer | Fluke Norma 4000: | No |
Fluke Norma 5000: | Yes (optional) | |
Display | Color, 5.7“ / 144 mm - 320 x 240 pixel | |
User-selectable background lighting and contrast. | ||
Bandwidth | dc to 3MHz or dc to 10MHz depending on input module | |
Basic Accuracy | 0.2%, 0.1% or 0.03% depending on input modules | |
Sampling Rate | 0.33 MHz or 1 MHz depending on input modules | |
Voltage Input Range | 0.3 V to 1000 V | |
Current Input Range (direct, not via shunt) | 0.03 mA to 20 A depending on input module | |
Memory for Configurations | 4 MB | |
Memory for Settings | 0.5 MB | |
Fast Fourier Transformation (FFT) | To the 40th harmonic | |
RS232/USB Interface | Standard | |
PI1 Process interface (8 analog/impulse inputs and 4 analog outputs) | Optional | |
IEEE 488.2/GPIB interface (1 MBit/s Ethernet / 10 MBit/s or 100 MBit/s) | Optional | |
Fluke NormaView PC software (for data download, analysis & report writing) | Standard | |
Basic Functions | ||
Fast Fourier Transformation (FFT) | Calculation of harmonics with graphical representation. Up to 3 bar graphs are displayed at the same time. | |
Measured values: U, I, P per phase | ||
Order: 1st to 40th harmonics, maximum half sample frequency | ||
Digital Oscilloscope (DSO) | Simultaneous display of up to 3 measured values on sample level. Quick view of curve form and distortion. | |
Integration function (energy) | Simultaneous display of up to 6 configurable numeric values. Start/Stop conditions and positive negative direction available. | |
Vector Display | Vector display of HO1 up to 6 signals. For easy testing of the right connection of the instrument and quick overview of the phase angle of each signal. | |
Recorder | Display of average values over time for trend determination. | |
RAM data memory | Storing of sample and average values; setting of start and stop conditions. | |
From the RAM approximately 4 MB are available for the storage of measured values. | ||
Configuration | Set up the analyzer to measure and display data in the format required. | |
Ambient Conditions | ||
Working Temperature Range | 5 °C to 35 °C (41 °F to 95 °F) | |
Storage Temperature Range | -20 °C to 50 °C (-4 °F to 122 °F) | |
Housing Material | Fluke Norma Power Analyzers are extremely compact and equipped with a solid metal case to meet stringent EMC requirements. | |
Climatic Class | KYG DIN 40040, max. 85 % relative humidity, non-condensing. | |
Power supply | 85 V ac to 264 V ac, 50 Hz to 60 Hz, dc 100 to 260 V, ca. 40 VA European plug with switch. Binding post for current available on some models. | |
Measuring Inputs | Safety sockets 4 mm, 2 for each input. External shunt connection over BNC socket. | |
Operation | Membrane keyboard with cursor – function keys and direct functions. | |
Connections | Rear panel of the 3-phase Analyzer | |
Measured Values | ||
Non-gapping calculation of averaged values for each phase. In three phase system additionally calculation of total power and averaging of V and I of the three phases. The fundamental H01 will be calculated in synchronous mode also for these values. | ||
Urms effective value, Urm rectified mean, Um mean value | ||
Up-, Up+, Upp peak values | ||
Ucf crest factor Ucf, Uff form factor | ||
Ufc fundamental content | ||
Uthd distortion factor DIN, IEC | ||
Irms effective value, Irm rectified mean, Im mean value | ||
Ip-, Ip+, Ipp peak values | ||
Icf crest factor Icf, Iff form factor | ||
Ifc fundamental content | ||
Ithd distortion factor DIN, IEC | ||
P active power [W] | ||
Q reactive power [Var] | ||
S apparent power [VA] | ||
ë, cos. phase angular | ||
Integral function for active power P, reactive power Q, apparent power S, voltage (Um) and current (Im), | ||
Number of digits 4 or 5 dependent on measured value. | ||
Frequency and Synchronization | ||
Range | DC and 0.2 Hz to sample rate | |
Accuracy | ±0.01 % of measured value (reading) | |
• | Channels which can be selected: all U/I or external input. | |
• | One of three low pass filter with different frequencies can be switched into the signal. | |
• | The frequency is always visible on the top of the screen. | |
• | The BNC synchronization socket on backside of the instrument can be used either as input or output. | |
• | The input signals can be measured up to the sample rate of the power phase. The maximum level must not be higher then 50V. | |
• | The output signal is a pulsed 5Volts TTL signal (frequency depends on the measured synch frequency). | |
Configuration Memory | ||
Up to 15 user configurations can be saved into a permanent memory and reloaded later on. Changes that were not saved are lost after switching off the instrument. | ||
Interface | ||
RS232 interface for upload of firmware and data exchange with the PC. A printer can be connected over an external converter. | ||
Options | IEEE 488.2 / 1 MBit/s | |
Ethernet / 10 MBit/s or 100 Mbit/s | ||
Standards and Safety | ||
Electrical Safety | EN 61010-1 / 2nd Edition 1000 V CAT II (600V CAT III) | |
Degree of pollution 2, safety Class I | ||
EN 61558 for transformer | ||
EN 61010-2-031/032 for accessories | ||
Maximum inputs | For voltage inputs Measurement range 1000 Veff, 2 kVpeak | |
For current inputs Measurement range 10 Aeff, 20 Apeak | ||
Test voltage | Net input | case (protective conductor): 1.5 KV AC |
Net connection | Measurement input: 5.4 kV AC | |
Measurement inputs | Case: 3.3 kV AC | |
Measurement input | input: 5.4 kV | |
Electromagnetic susceptibility | Emission: | IEC 61326-1, EN 50081-1, EN 55011 Class B |
Immunity: | IEC 61326-1 / Annex A (industrial sector), EN 50082-1 |