Specifications
|
||
Test Voltage 250 V DC | Range: | 200 kΩ to 5 GΩ |
Accuracy: | 5% | |
Range: | 5 GΩ to 50 GΩ | |
Accuracy: | 20% | |
Test Voltage 500 V DC | Range: | 200 kΩ to 10 GΩ |
Accuracy: | 5% | |
Range: | 10 GΩ to 100 GΩ | |
Accuracy: | 20% | |
Test Voltage 1000 V DC | Range: | 200 kΩ to 20 GΩ |
Accuracy: | 5% | |
Range: | 20 GΩ to 200 GΩ | |
Accuracy: | 20 | |
Test Voltage 2500 V DC | Range: | 200 kΩ to 50 GΩ |
Accuracy: | 5% | |
Range: | 50 GΩ to 500 GΩ | |
Accuracy: | 20% | |
Test Voltage 5000 V DC | Range: | 200 kΩ to 100 GΩ |
Accuracy: | 5% | |
Range: | 100 GΩ to 1 TΩ | |
Accuracy: | 20% | |
Short circuit current | > 1 mA and < 2 mA | |
Bar graph | Range: | 0 to 1 TΩ |
Insulation test voltage | Accuracy: | 0% to 10% at 1 mA load current |
Induced AC mains current rejection | Max: | 2 mA |
Charging rate for capacitive load | 5 s/µF | |
Leakage current | Range: | 1 nA to 2 mA |
Accuracy: | ±(5% + 2 nA) | |
Capacitance measurements | Range: | 0.01 µF to 15.00 µF |
Accuracy: | ±(15% rdg + 0.03 µF) | |
Live circuit indicator | Range: | 30 V to 600 V (AC/DC, 50/60 Hz) |
Accuracy: | ±(5% + 2V) | |
Timer | 1 - 99 minutes | |
Settable: | 1 minute increments | |
Indication: | 1 second resolution | |
Ramp | 0% to 100% of selected test voltage, or until breakdown | |
Environmental Specifications | ||
Operating Temperature | -20°C to +50°C (-4°F to 122°F) | |
Storage Temperature | -20 °C to +65 °C (-4°F to 149°F) | |
Humidity (Without Condensation) | 80% at 31 °C (87.8°F), 50% at 50 °C (122°F) | |
Dust/water resistance | IP-40 | |
Operating Altitude | 2,000 m | |
Safety Specifications | ||
Safety Rating | EN 61010-1, CAT III 600V, EN61557, Parts 1 & 2 | |
EMI immunity | EN 61326 | |
Mechanical & General Specifications | ||
Size | 170mm x 242mm x 330 mm (6.7" x 9.5" x 13.0") | |
Weight | 4 kg (with battery) (8.8 lbs) | |
Batteries | 12 V, lead-acid, rechargeable | |
Warranty | 2 years | |
Battery Life | Test voltage: | Number of tests |
250 V: | 4100 | |
500 V: | 3600 | |
1000 V: | 3200 | |
2500 V: | 2500 | |
5000 V: | 1500 | |
Shock & Vibration | MIL-PRF-28800F, Class II | |
Charger input | AC: | 85 to 250 V AC, 50/60 Hz, 50 VA |