![]() ![]() | MOISTURE CONTROL FOR INDUSTRIAL PROCESSES Mission Statement To be at the forefront of hygrometer supply, design and innovation through continuous Research & Development, thus maintaining our competitive edge through lower costs and consistent high quality. The extensive range of user friendly, microprocessor controlled dewpoint meters, hygrometers and sampling systems have been designed to meet the most demanding requirements and needs expressed by the industry. Our in-house capability to design and prototype enables us to manufacture bespoke equipment to customers requirements and specifications. The products are built using quality components, to the highest standards and specifications, compliant with our quality system which is accredited to ISO 9001:2008. We can therefore offer all our products with a generous warranty, guaranteeing reliability and performance.
|
APPLICATIONS |
Some Typical applications include:Sulphur Hexafluoride Used in Circuit Breakers Sulphur hexafluoride is used as an insulating gas in circuit breakers. Excess moisture in SF6 gas causes arcing, which can trip the circuit breaker and cut off power to the distribution network. Moisture in Natural Gas Liquid Benzene Feed Stock Vacuum-Evacuation and Gas Refill in Oil Filled Transformers Instrument Air Breathing Air Hydrogen Annealing Ovens Ethylene Gas Stream for High-Density Polyethylene Production High moisture content in the Ethylene feed gas reduces the catalyst activity, thereby decreasing the overall yield of the polyethylene reactors.Hydrogen Cooled Electric Generators Hydrogen is used to cool large stationary generators because of its high heat capacity and low viscosity. The hydrogen must be kept dry in order to maintain both its heat capacity and viscosity properties. Ambient moisture is considered a contaminant which will reduce the heat capacity and increase the viscosity of the cooling hydrogen. Injection Moulding 1. Excess moisture decreases the strength of the product. All of these production defects reduce product yield and escalate production costs.Nuclear Reactors The Advance Gas Cooled Reactor uses carbon dioxide gas to transfer heat from the nuclear fission core to the water boiler for steam generation. The moisture content needs to be kept low to avoid corrosion damage, and the moisture monitoring will also act as a leak detector. Packaging Foods |
Alpha Moisture Systems'' range of portable hygrometers and dewpoint analysers have been designed with the requirements of the industrial user in mind. All instruments are fully self-contained and combine robust construction with microprocessor based electronics, to ensure that they consistently provide the operator with accurate and repeatable results. The user friendly range of instruments all incorporate the unique Desiccant Dry-Down Chamber assembly (see below), which enables the operator to obtain instantaneous readings in either the field or laboratory. Designed to operate using universally available standard batteries, the analysers can be continuously used in excess of 250 hours. Combining robust construction of high quality, fully interchangeable sensor technology and full after sales support, the portable analysers are guaranteed to provide a long and reliable service. All portable analysers are supplied ready for use with batteries installed, calibration certificate traceable to National and International Humidity Standards, two metres of sampling hose and detailed instruction manual. Contact us for further information. Click on a product name below for more information.
The key to the operation of Alpha Moisture Systems'' Portable Analysers is the unique Desiccant Dry-Down Chamber. By keeping the sensor dry between tests, the special assembly of the head ensures that the instrument is always ready for immediate use. The head assembly consists of two chambers which have a telescopic action. When the head assembly is in the ''closed'' or ''Dry-Down'' position, the sensor is completely surrounded by desiccant, which absorbs the remaining water moisture from the sensor and hence it is dry and ready for use. The small space at the bottom of the test chamber enables the sample pipe to be purged before the test commences without wetting the sensor. By placing a finger over the outlet of the head, the sample pressure is able to open the test chamber automatically, exposing the sensor to the gas being tested and enabling accurate reading of moisture content in the sample gas. After each test the head assembly is closed by depressing the inner section so that the sensor will again be dried by the desiccant, leaving the sensor ready for use time and time again. The desiccant is kept in the inner chamber and is not exposed to ambient room air or the sample gas, therefore there is no need for frequent regeneration or replacement of the desiccant. | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Alpha Moisture Systems'' range of single channel moisture analysers have been developed to meet the requirements of all applications, requiring on-line analysis at a single sample point. These instruments combine robust construction and advanced electronics to ensure that they will provide accurate moisture analysis through a long and reliable service life.Unless stated otherwise, all on-line analysers are used in conjunction with any of our range of dedicated Ultra High Capacitance moisture sensors covering an overall range from -110ºC to +20ºC dewpoint, 0.001 to 23,000 ppm(v). Pleasecontact us for further information. With a broad range of applications for moisture analysis, from laboratory based R&D work to OEM equipment, no manufacturer can claim to meet all applications with a single instrument. Our range of on-line analysers combine various cabinet types from compact panel mount to robust weatherproof or bench mounting cabinets, with power supply, electrical output and indication options. All in all, the customer can be assured that whatever the application, we will have a moisture analyser which will not be beaten for long term reliability and accuracy, tailored to meet exact requirements. Click on a product name below for more information.
|
![]() | Model DS1200 - Single Channel Analyser
|
Model DS1200 from Alpha Moisture Systems is a single channel on-line hygrometer designed to measure dewpoint in process gases and dry compressed air. The panel mounted ? DIN dewpoint meter, providing panel protection to IP65 (NEMA4X), combines with the Model AMT range of ultra high capacitance sensors for accurate trace moisture measurement. Combination of advanced digital technology of the display electronics and the sensor, makes this the system of choice for a wide range of applications where precise indication, control and monitoring is critical. Model DS1200-AMT system can be factory configured to read in °C dewpoint, °F dewpoint, ppm(v), ppb(v), g/m³ or lbs/MMSCF. The measured value is displayed on a large 4 digit, 13.8mm high, fourteen segment LED display. The instrument offers two fully programmable alarm relays, which can be independently set across the full operating range of the sensor. An optically isolated analogue signal, linear with the measured unit, is also available to interface with any external device. Model DS1200-AMT can be supplied with any one of a range of sensors, which have all been specially manufactured to provide long term stability, so ensuring a long and trouble free service life. The long lasting sensing element offers excellent sensitivity, repeatability and response speed - especially on dry down. Integrated electronics in each sensor allows calibration data to be stored within its memory, making sensors completely field interchangeable. Each sensor is calibrated to provide overall system accuracy of better than ±2°C dewpoint and supplied with a certificate traceable to international humidity standards. Model DS1200-AMT also incorporates the invaluable “AUTOCAL” feature for easy field verification of the system response, without recourse to any additional equipment. Accidental or unauthorised operation is prevented by a simple initiation routine. The system allows the display console to be sited in excess of 1000m from the sensor, connected by a simple twisted pair cable. Model DS1200-AMT Dewpoint Hygrometer is fully configured according to the customer''s specifications and is supplied complete with 2 metres of connecting cable and user manual. For ease of installation, an optional flow through sample cell can be ordered together with suitable pipe connections. (For full details please request specification sheet Model DS1200) |
![]() | Model DS2000 - Single Channel Dewpoint Analyser
Model DS2000 is a single channel, on-line hygrometer designed to accurately measure dew point in process gases and dry compressed air. This panel mounted, large 5½ digit, seven segment LED display is fully self-contained in 1/8 DIN panel mounted case providing front panel protection to IP66 (NEMA 4). Advanced digital technology together with the industry''s leading ultra high capacitance aluminium oxide dewpoint sensors, makes this the unit of choice for a wide range applications due to it''s flexibility, high configurability and ease of use through its menu driven operation. Features include two independent, fully user programmable alarm contacts and open collector outputs. Linear current or voltage (factory set) output is available as well as RS485 serial connection. (For full details please request specification sheet Model DS2000) |
|