Td-1000 C Oil In Water Monitor | Turner Designs Hydrocarbon Instruments | Pitesco Vietnam Đại Lý Phân Phối

Liên hệ

D5 Miếu Nổi, Đinh Tiên Hoàng, P.3, Q.bình Thạnh


Công ty TNHH kỹ thuật công nghệ và dịch vụ Tiên Phong

D5 KDC Miễu Nổi, Đinh Tiên Hoàng, P3, Q.Bình Thạnh

Tell : 0915.980.479

        0162.999.888.7

Email : vinhmv.pitesco@gmail.com

TD-1000 CPrint


Download Technical Data Sheet

Measures Oil in Water: Continuous on-line monitor measures ppb or ppm 
oil in water

Boiler, Cooling System and Environmental Protection with earliest oil leak detection on the market

UV Fluorescence technology provides highest sensitivity available 

Highest sensitivity = lowest detection limit = earliest warning of oil contamination

 


ApplicationsSteam Condensate, Boiler Feed, Cooling Water, Clean Water
Operational PrincipleUV Fluorescence
HydrocarbonsFuel Oil, Crude Oil, Other Fuels and Oils
Detection Range Fuel Oil, Crude Oil20ppb in Steam Condensate - 500ppm
Response Time5 seconds spike change, continuous reading
Local DisplayPPM, PPB, Or Raw Fluorescence Units (RFU)
ControlsExternal Touch Pad
Power Requirements90 - 250 VAC, 5A
AlarmsSolid State AC Relay High Alarm (3A fused, 90 - 250 VAC), 5VDC Cell Condition Alarm, 5VDC System Alarml
Outputs4-20mA Powered, 500ohm. Max Impedance
DiagnosticsSelf Diagnostics, internal failure linked to alarm
Communication Protocols(Unidirectional Hart, Mod Bus Optional)
Mounting & Plumbing Hardware316 SS
Plumbing RequirementsSee General Arrangement Drawing
Flow Cell CharacteristicQuartz Closed Tube with Cell Contition Monitor and Alarm
Pressurized Sample ReturnYes, or Unpressurized to Drain
Typical Flow Rates100mL/min to 4L/min
Min / Max Sample Pressure5psig / 100psig, 0.35barg / 6.9barg
Max Sample Temperature71°C, 160°F (Sample Cooler is Optional)
Ambient Operating Temperature32°F - 120°F, 0°C - 49°C
Calibration Stability+/- 10% over 6 Months
CalibrationBlank / Standard Addition via Syringe Injection Port
ReagentsNone
SecurityPassword Protected
Communication ProtocolsOptional: Hart, Mod Bus
DiagnosticsSelf Diagnostics, internal failure linked to alarm, Cell Condition
SecurityPassword Protects Software, Lockable Enclosure
Electronics CabinetNon Metallic
Enclosure RatingApproximates NEMA 4X and IP 65
MaintenanceCalibration Check, Clean Flow Cell on Alarm
Cleaning ChemicalsDetergents, Dilute HCL, or Solvents (Customer Furnished)
Explosion Proof OptionsGen Purpose Only (Use TD-4100 XDC for Explosion Proof Areas)
Sample PumpOptional
CertificationsCE Marked, CUL