Unitronics Vision290™

Liên hệ

D5 Miếu Nổi, Đinh Tiên Hoàng, P.3, Q.bình Thạnh

PITESCO Việt Nam - Công ty XNK hàng đầu và là nhà cung cấp chuyên nghiệp các mặt hàng tự động, thiết bị điện và điện công nghiệp. Chúng tôi đáp ứng xu hướng công nghiệp hóa, hiện đại hóa.

Liên hệ cho chúng tôi theo số: 0963. 922.287 để được tư vấn 

Email :  linh.pitesco@gmail.com 

 Văn phòng Đồng Nai

261 tổ 19,QL 51, Kp 1, P Long Bình Tân, Tp Biên Hòa, Đồng Nai

Vision290™ : PLC with Touchscreen Graphic HMI & Snap-in I/O Modules 

The Vision290™ is a powerful PLC with a built-in HMI Operator Panel, comprising a 5.7” graphic touchscreen display with a virtual keypad. On-board I/Os can be added by simply snapping a module onto the back of the PLC; Snap-in I/O Modules come in several configurations. I/O Expansion modules enable integrating up to 316 I/Os per Vision PLC. 

The Vision290™offers a rich range of embedded features such as multiple auto-tuned PID loops, internal 120K structured data table and loadcell support. Communication options include TCP/IP, Ethernet, GSM/SMS, MODBUS, CANbus networking, function blocks that enable Vision to communicate with devices using proprietary COM protocols, plus remote access and data export software utilities. 
1M-Ladder code application memory enables the Vision290™ to run complex control and automation tasks. 

The touchscreen HMI enables the display of ‘touchable’ images and text according to real-time conditions—for on-line operation and diagnostics. It can also display graphs according to historical values—to reflect trends of recorded data. Display options are almost endless with up to 255 user-designed screens, and up to 24 HMI variables per screen.

The Vision PLC/Graphic HMI series introduces an unbeatable price-performance ratio, enabling users to enjoy the advanced features of both the operator panel and the PLC, while maintaining low budget, reduced programming time and minimum wiring.




Specifications 


PLC


  • Supports up to 171 I/Os via Snap-in or Expansion Modules (number/type vary according to model)
  • I/O types: Digital (including shaft-encoder inputs & PWM outputs), Analog, & Temperature/weight measurement
  • Application memory: 1000K
  • Execution time: 0.5µsec for bit operation
  • Multiple built-in PID loops, including auto-tune
  • Data Tables: 120K (RAM) & 192K (Flash) for dynamic data logging and production recipes

 

HMI


  • Display ‘touchable’ images, text and graphs according to real-time conditions and historical values
  • ‘Touch’ properties can be assigned to all text and graphic on-screen elements
  • Data entry/modification via keypad
  • Up to 255 user-designed displays
  • 24 variables per display; link up to 150 images/messages to each variable
  • Use hundreds of images in one application
  • Graphic display screen: 5.7”, 320 x 240 pixels (QVGA)
  • LCD illuminated screen
  • Virtual keyboard
  • Info mode: view/modify I/O status, integer values, and system data via the panel

Communications


  • RS232 port
  • RS232/RS485 port
  • Ethernet/additional RS232/RS485 port (optional)
  • GSM/SMS support
  • Remote access via network GPRS, GSM, CDMA or landline modems
  • MODBUS (master/slave)
  • CANbus and UniCAN
  • OPC/DDE server
  • Additional communication protocols

Our HMI/PLC programming software and software utilities are free to all Unitronics clients



Snap-in I/Os 


Vision series controllers can be installed with a snap-in I/O module. The Snap-in I/O Module snaps onto the back of the Vision. Unitronics’ range of I/O modules ensures flexible configurations that will fit your system’s precise requirements.









V200-18-E1B


  • 16 pnp/npn Digital inputs, 24VDC
  • (including two high-speed counters/ Shaft encoder/ Frequency measurer, 10kHz)
  • 3 Analog inputs, 10 bit, 0-10V, 0-20mA
  • 10 Relay outputs
  • 4 pnp/npn outputs, 24VDC
    (including two high-speed outputs/ PWM, 50kHz for npn / 0.5 kHz for pnp) 









V200-18-E2B


  • 16 pnp/npn Digital inputs, 24VDC.
  • (including two high-speed counters/ Shaft encoder/ Frequency measurer, 10kHz).
  • 2 Analog inputs, 10 bit, 0-10V, 0-20mA.
  • 10 Relay outputs.
  • 4 pnp/npn outputs, 24VDC.
  • (including two high-speed outputs/ PWM, 50kHz for npn / 0.5 kHz for pnp).
  • 2 Analog outputs, 12 bit, 0-10V, 0-20mA, 4-20mA.









V200-18-E3XB


  • 18 pnp/npn Digital inputs, 24VDC.
    (including two high-speed counters/ Shaft encoder/ Frequency measurer, 10kHz).
  • 4 Isolated Analog/Thermocouple/PT100 inputs (Analog: 14 bit, 0-10V, 0-20mA. Thermocouple/PT100: 0.1° resolution).
  • 15 Relay outputs.
  • 2 pnp/npn outputs, 24VDC.
    (including two high-speed outputs/ PWM, 50kHz for npn / 0.5 kHz for pnp).
  • 4 Analog outputs, 12 bit, 0-10V, 4-20mA.









V200-18-E4XB


  • 18 pnp/npn Digital inputs, 24VDC.
    (including two high-speed counters/ Shaft encoder/ Frequency measurer, 10kHz).
  • 4 Isolated Analog/Thermocouple/PT100 inputs.
    (Analog: 14 bit, 0-10V, 0-20mA. Thermocouple/PT100: 0.1° resolution).
  • 15 Isolated pnp outputs.
  • 2 Isolated pnp/npn outputs, 24VDC.
    (including two high-speed outputs/ PWM, 50kHz for npn / 0.5 kHz for pnp).
  • 4 Analog Isolated pnp/npn outputs, 12 bit, 0-10V, 4-20mA.









V200-18-E5B


  • 18 pnp/npn digital inputs, 24VDC.
    (including two high-speed counters/ Shaft encoder/ Frequency measurer, 10kHz).
  • 3 Analog inputs, 10 bit, 0-10V, 0-20mA, 4-20mA.
  • 15 Isolated pnp outputs.
  • 2 Isolated pnp/npn outputs, 24VDC.
    (including two high-speed outputs/ PWM, 50kHz for npn / 0.5 kHz for pnp).







V200-18-E6B



  • 18 pnp/npn Digital inputs, 24VDC
    (including two high-speed counters/ Shaft encoder/ Frequency measurer, 10kHz).
  • 2 Analog/Thermocouple/PT100 inputs (Analog: 14 bit, 0-10V, 0-20mA, 4-20mA. Thermocouple/PT100: 0.1° resolution)
  • 3 Analog (10 bit, 0-10V, 0-20mA, 4-20mA)
  • 15 Relay outputs
  • 2 pnp/npn outputs, 24VDC
    (including two high-speed outputs/ PWM, 50kHz for npn / 0.5 kHz for pnp)
  • 2 Analog outputs, 12 bit, 0-10V, 4-20mA



V200-18-E62B


  • includes 2 shaft encoder inputs.
  • 28 isolated pnp outputs.
  • 2 isolated pnp/npn (source/sink) transistor outputs, includeshigh-speed outputs.
  • 2 analog inputs.



V200-18-E46B


  • 18 npn/pnp Digital inputs (including 2 shaft-encoder inputs)
  • 3 Analog inputs (10-Bit), 6 (12 or 14 Bit).
    0-10V. 0-20mA, 4-20mA
  • 2 npn/pnp HighSpeed Digital Outputs
  • 15 Relay Outputs
  • 2 Isolated Analog Outputs















I/O Expansions




Expand your system with a wide variety of Unitronics'''' remote or local I/O expansion modules, An I/O expansion adapter allows you to connect various local or remote I/O combinations to Vision series PLCs.
The M90/M91PLCs support local modules only.

EX-A2X

Local expansion adapter—used to link between the PLC and up to 8 expansion modules (no. of I/Os may vary according to model). Supports both 12/24VDC.











IO-AI4-AO2

24VDC (power supply) 
4 Analog inputs, 12 bit, 0-10V, 0-20mA, 4-20mA 
2 Analog outputs, 12 bit + sign, 0-10V, 0-20mA, 4-20mA. 








IO-AO6X

24VDC (power supply) 
6 Isolated Analog outputs, 12 bit, 0-10V, 0-20mA, 4-20mA.








IO-PT4

4 PT100 inputs, range: -50°C : 460°C (-58°F : 860°F), 12 bit.







IO-PT400

4 PT100 / NI100 / NI120 inputs, 
Range PT100: -50°C : 460°C (-58°F : 860°F)
Range NI100: -50°C : 232°C (-58°F : 449°F)
Range NI120: -50°C : 172°C (-58°F : 341°F)
12 bit.







IO-PT4K

4 PT1000 / NI1000 inputs
Range PT1000: -50oC ÷ 460oC, (-58oF ÷ 860oF)
Range NI1000: -50oC ÷ 232oC, (-58oF ÷ 449oF)
12 bit









IO-ATC8

8 Thermocouple/Analog inputs (T/C: J, K, T, B, E, N, R, S, 0.1° resolution. Analog: 12/14 bit, 0-10V, 0-20mA, 4-20mA).







IO-LC1

12/24VDC (power supply) 
1 Loadcell / Strain gauge input. Voltage range: ±20mV, ±80mV, execution: AC/DC
1 Digital pnp input
2 setpoint pnp outputs
(* Not supported by the M90 line).








IO-LC3

12/24VDC (power supply) 
3 Loadcell / Strain gauge inputs. Voltage range: ±20mV, ±80mV, execution: AC/DC 
1 Digital pnp input 
2 setpoint pnp outputs 
(* Not supported by the M90 line).








IO-D16A3-RO16

24VDC
16 Digital pnp/npn inputs, including 2 High-speed counters
3 Analog inputs, 10 bit, 0-20mA, 4-20mA 
16 Relay outputs

3D View







IO-D16A3-TO16

24VDC 
16 Digital pnp/npn inputs, including 1 High-speed counter
3 Analog inputs, 10 bit, 0-20mA, 4-20mA 
16 Transistor pnp/npn outputs, including 1 High-speed output

3D View







EX-D16A3-RO8

24VDC 
16 Digital pnp/npn inputs, including 2 High-speed counters 
3 Analog inputs, 10 bit, 0-20mA, 4-20mA 
8 Relay outputs
Adapter not required.







EX-D16A3-TO16

24VDC 
16 Digital pnp/npn inputs, including 1 High-speed counter 
3 Analog inputs, 10 bit, 0-20mA, 4-20mA 
16 Transistor pnp/npn outputs, including 1 High-speed output
Adapter not required.







IO-DI8-TO8

24VDC 
8 Digital pnp/npn inputs, including 1 High-speed counter 
8 Transistor pnp outputs.
Supports Fast-response (in conjunction with Vision PLCs)









IO-DI8-RO8

24VDC 
8 Digital pnp/npn inputs, including 1 High-speed counter 
8 Relay outputs.







IO-DI8-RO4

24VDC 
8 Digital pnp/npn inputs, including 1 High-speed counter 
4 Relay outputs.









IO-DI16

24VDC 
16 Digital pnp/npn inputs, including 1 High-speed counter.







IO-TO16

12/24VDC 
16 Transistor pnp outputs.







IO-RO8

24VDC (power supply) 
8 Relay outputs.







IO-RO16

24VDC (power supply) 
16 Relay outputs.







EX90-DI8-RO8

24VDC 
8 Digital pnp inputs, including 1 High-speed counter 
8 Relay outputs 
(This unit is housed in an open casing. Only one EX90 can be connected per PLC, as a single expansion module; EX-A1 adapter not required).










IO-DI8-TO8-L

8 Digital pnp/npn inputs, including 1 High-speed counter 
8 Transistor pnp outputs.







IO-DI8-RO8-L

12VDC 
8 Digital pnp/npn inputs, including 1 High-speed counter 
8 Relay outputs.







IO-DI8-RO4-L

12VDC 
8 Digital pnp/npn inputs, including 1 High-speed counter 
4 Relay outputs.










IO-RO8-L

12VDC (power supply) 
8 Relay outputs.







IO-RO16-L

12VDC (power supply) 
16 Relay outputs.







IO-DI8ACH

110/220 VAC
8 AC Inputs









IO-AI8

I/O Expansion Module with 8 analog inputs 
0÷10V/0÷20mA
14 bit







 




Communication Modules 

An additional COM module can be installed in any Vision530™ unit.




 


V200-19-ET1

1 Ethernet port






   


V200-19-RS4

1 RS232/RS485 port






   


V200-19-RS4X

1 RS232/RS485 port (Isolated) 

   










Special Features

 


Flexible PID

Up to 12 built-in PID loops, including internal auto-tune, ramp-soak programmer and bumpless transfer. Use Vision’s PID loops to economically and efficiently combine accurate process control with the flexibility of a PLC




 


Data Tables 

Use Vision’s smart data tables (120K RAM and 192K Flash memory), to log dynamic data and store production recipes. 





 


Shaft-encoder Inputs

Use the controller’s integral 10kHz inputs as high-speed counters, frequency measurers, or to directly connect to shaft-encoders. 





 


PWM Outputs

Control stepper motors or PID-based applications, via PWM, with the Vision120''''s onboard PWM outputs (model-dependent).





 


Easy Scrolling between Recipes

Simply scroll between pre-programmed recipes or menus, using the panel’s arrow keys. This enables you to choose and activate a desired task via the HMI - immediately, on-site. 







Image Library

Easily design your graphic displays using the Vision’s extensive image library.





 


Temperature & Weight measurement

Onboard direct temperature inputs (PT100 or Thermocouple) give you the ability to control temperature-based applications, 
Loadcell I/O Expansion Modules enable you to hook up weight/strain inputs and achieve accurate measurements—no additional hardware required. 
(M91 series only, features are model-dependant) 





 


Time-based Control

Do you need a specific task to be performed at a specific time and date? Simply mark the hour, date or weekday in the PLC software—and you have created time-based control in 3 clicks. 






Information Mode 

Press the key on the operator panel to enter the PLC’s Information Mode, providing you with powerful diagnostic capabilities. 




Virtual Keyboard

Application requires data entry? The Vision''''s virtual keyboard pops up automatically.































Communication

Ethernet
GPRS
GSM/SMS
Remote Access
MODBUS 
CANbus
OPC/DDE Server
Additional Communication Protocols
DataXport (to Excel)


Ethernet via TCP/IP 

Use your factory’s existing LAN wiring to implement stable, high-speed control. Ethernet, the universal COM standard is embedded in Vision controllers. 
Ethernet enables MODBUS or open protocol commands to run over TCP/IP. Via the Ethernet port (purchased separately) and easy-to-use Ladder function blocks, Vision can:


  • Exchange data, PLC to PLC
  • Access external slave devices that support TCP/IP
  • Use MODBUS IP or OPC to implement PC access via SCADA
  • Acquire data from remote Vision units, networked into Intranets, Internets and wireless LANs
  • Boost your connectivity by using dedicated IP address—and access/program remote Vision PLCs via the Internet


GPRS

Use GPRS wireless data transmission services to access your Vision PLC via the Internet. Vision can transmit IP packets of data to a remote PC connected to the Internet via GPRS modem, using a dedicated IP. 
GPRS enables you to operate remote PLCs on-line, upload, download, debug programs, and log application data—no wires required. 


GSM/SMS 

Use your cellular phone to implement real-time remote control in your application. Vision PLCs can send and receive SMS messages to/from any GPRS/GSM/CDMA cellular phone. The SMS-enabled controllers can:


  • Send & receive text and variable SMS messages

  • Route different messages to different phone numbers

  • Auto-acknowledge received messages

  • Answer data requests from your cell phone, directly to your cell phone


Remote Access

Use your PC to access remote PLCs via network connections, Ethernet, cellular (GPRS/GSM/CDMA) or landline modems. Unitronics’ unique Remote Access utilities enable you to remotely:


  • Run, reset, or initialize a controller
  • Download, upload, or debug PLC programs
  • Read, write, and store online operand and system values


MODBUS

Use serial or TCP/IP MODBUS to create a multi-device network, and establish master-slave communication between Unitronics PLCs and any connected device that supports the MODBUS protocol (SCADA systems, servos and other peripheral devices). Any Unitronics controller in the network may function as either master or slave.

CANbus 

CANopen: communicate with remote devices, ranging from simple, fast I/O-related devices such as encoders, to complex frequency converters. Compliant with CiA DS 301.

UniCAN: use Unitronics'''' protocol to integrate up to 60 units into a high-speed network, and to transfer up to 512 MI register values during a single program scan.

CAN Layer 2


OPC/DDE Server


Unitronics’ OPC/DDE servers enable the PLC to exchange data with external applications. Use it to interface with SCADA systems, or to read/write PLC data from/to Excel, Access, or other Windows-based applications.

OPC/DDE Server software utilities are free downloads.


Additional Communication Protocols

The “Protocols” function block enables the Vision PLC to communicate, via RS232 and RS485, with a broad variety of external devices, such as bar-code readers and servos. 


DataXport (to Excel)

A powerful software utility that captures PLC application data and exports it to Excel files for logging or processing. Data is exported, either directly, via network connection, or via modem, according to a user-defined schedule, or is pulled manually to view current status.







Bình luận

HẾT HẠN

0963 922 287
Mã số : 9114012
Địa điểm : Hồ Chí Minh
Hình thức : Cần bán
Tình trạng : Hàng mới
Hết hạn : 17/12/2020
Loại tin :

Thường

Để mua hàng an toàn trên Rao vặt, quý khách vui lòng không thực hiện thanh toán trước cho người đăng tin!

Gợi ý cho bạn