Specifications
PLC
- Supports up to 171 I/Os via Snap-in or Expansion Modules (number/type vary according to model)
- I/O types: Digital (including shaft-encoder inputs & PWM outputs), Analog, & Temperature/weight measurement
- Application memory: 1000K
- Execution time: 0.5µsec for bit operation
- Multiple built-in PID loops, including auto-tune
- Data Tables: 120K (RAM) & 192K (Flash) for dynamic data logging and production recipes
HMI
- Display ‘touchable’ images, text and graphs according to real-time conditions and historical values
- ‘Touch’ properties can be assigned to all text and graphic on-screen elements
- Data entry/modification via keypad
- Up to 255 user-designed displays
- 24 variables per display; link up to 150 images/messages to each variable
- Use hundreds of images in one application
- Graphic display screen: 5.7”, 320 x 240 pixels (QVGA)
- LCD illuminated screen
- Virtual keyboard
- Info mode: view/modify I/O status, integer values, and system data via the panel
Communications
- RS232 port
- RS232/RS485 port
- Ethernet/additional RS232/RS485 port (optional)
- GSM/SMS support
- Remote access via network GPRS, GSM, CDMA or landline modems
- MODBUS (master/slave)
- CANbus and UniCAN
- OPC/DDE server
- Additional communication protocols
Our HMI/PLC programming software and software utilities are free to all Unitronics clients
Snap-in I/Os
Vision series controllers can be installed with a snap-in I/O module. The Snap-in I/O Module snaps onto the back of the Vision. Unitronics’ range of I/O modules ensures flexible configurations that will fit your system’s precise requirements.
V200-18-E1B
- 16 pnp/npn Digital inputs, 24VDC
- (including two high-speed counters/ Shaft encoder/ Frequency measurer, 10kHz)
- 3 Analog inputs, 10 bit, 0-10V, 0-20mA
- 10 Relay outputs
- 4 pnp/npn outputs, 24VDC
(including two high-speed outputs/ PWM, 50kHz for npn / 0.5 kHz for pnp)
V200-18-E2B
- 16 pnp/npn Digital inputs, 24VDC.
- (including two high-speed counters/ Shaft encoder/ Frequency measurer, 10kHz).
- 2 Analog inputs, 10 bit, 0-10V, 0-20mA.
- 10 Relay outputs.
- 4 pnp/npn outputs, 24VDC.
- (including two high-speed outputs/ PWM, 50kHz for npn / 0.5 kHz for pnp).
- 2 Analog outputs, 12 bit, 0-10V, 0-20mA, 4-20mA.
V200-18-E3XB
- 18 pnp/npn Digital inputs, 24VDC.
(including two high-speed counters/ Shaft encoder/ Frequency measurer, 10kHz). - 4 Isolated Analog/Thermocouple/PT100 inputs (Analog: 14 bit, 0-10V, 0-20mA. Thermocouple/PT100: 0.1° resolution).
- 15 Relay outputs.
- 2 pnp/npn outputs, 24VDC.
(including two high-speed outputs/ PWM, 50kHz for npn / 0.5 kHz for pnp). - 4 Analog outputs, 12 bit, 0-10V, 4-20mA.
V200-18-E4XB
- 18 pnp/npn Digital inputs, 24VDC.
(including two high-speed counters/ Shaft encoder/ Frequency measurer, 10kHz). - 4 Isolated Analog/Thermocouple/PT100 inputs.
(Analog: 14 bit, 0-10V, 0-20mA. Thermocouple/PT100: 0.1° resolution). - 15 Isolated pnp outputs.
- 2 Isolated pnp/npn outputs, 24VDC.
(including two high-speed outputs/ PWM, 50kHz for npn / 0.5 kHz for pnp). - 4 Analog Isolated pnp/npn outputs, 12 bit, 0-10V, 4-20mA.
V200-18-E5B
- 18 pnp/npn digital inputs, 24VDC.
(including two high-speed counters/ Shaft encoder/ Frequency measurer, 10kHz). - 3 Analog inputs, 10 bit, 0-10V, 0-20mA, 4-20mA.
- 15 Isolated pnp outputs.
- 2 Isolated pnp/npn outputs, 24VDC.
(including two high-speed outputs/ PWM, 50kHz for npn / 0.5 kHz for pnp).
V200-18-E6B
- 18 pnp/npn Digital inputs, 24VDC
(including two high-speed counters/ Shaft encoder/ Frequency measurer, 10kHz). - 2 Analog/Thermocouple/PT100 inputs (Analog: 14 bit, 0-10V, 0-20mA, 4-20mA. Thermocouple/PT100: 0.1° resolution)
- 3 Analog (10 bit, 0-10V, 0-20mA, 4-20mA)
- 15 Relay outputs
- 2 pnp/npn outputs, 24VDC
(including two high-speed outputs/ PWM, 50kHz for npn / 0.5 kHz for pnp) - 2 Analog outputs, 12 bit, 0-10V, 4-20mA
 
V200-18-E62B
- includes 2 shaft encoder inputs.
- 28 isolated pnp outputs.
- 2 isolated pnp/npn (source/sink) transistor outputs, includeshigh-speed outputs.
- 2 analog inputs.
 
V200-18-E46B
- 18 npn/pnp Digital inputs (including 2 shaft-encoder inputs)
- 3 Analog inputs (10-Bit), 6 (12 or 14 Bit).
0-10V. 0-20mA, 4-20mA - 2 npn/pnp HighSpeed Digital Outputs
- 15 Relay Outputs
- 2 Isolated Analog Outputs
 
|
I/O Expansions Expand your system with a wide variety of Unitronics'''' remote or local I/O expansion modules, An I/O expansion adapter allows you to connect various local or remote I/O combinations to Vision series PLCs. The M90/M91PLCs support local modules only. EX-A2XLocal expansion adapter—used to link between the PLC and up to 8 expansion modules (no. of I/Os may vary according to model). Supports both 12/24VDC. IO-AI4-AO2
24VDC (power supply) 4 Analog inputs, 12 bit, 0-10V, 0-20mA, 4-20mA 2 Analog outputs, 12 bit + sign, 0-10V, 0-20mA, 4-20mA. IO-AO6X
24VDC (power supply) 6 Isolated Analog outputs, 12 bit, 0-10V, 0-20mA, 4-20mA. IO-PT4
4 PT100 inputs, range: -50°C : 460°C (-58°F : 860°F), 12 bit. IO-PT400
4 PT100 / NI100 / NI120 inputs, Range PT100: -50°C : 460°C (-58°F : 860°F) Range NI100: -50°C : 232°C (-58°F : 449°F) Range NI120: -50°C : 172°C (-58°F : 341°F) 12 bit. IO-PT4K4 PT1000 / NI1000 inputs Range PT1000: -50oC ÷ 460oC, (-58oF ÷ 860oF) Range NI1000: -50oC ÷ 232oC, (-58oF ÷ 449oF) 12 bit IO-ATC8
8 Thermocouple/Analog inputs (T/C: J, K, T, B, E, N, R, S, 0.1° resolution. Analog: 12/14 bit, 0-10V, 0-20mA, 4-20mA). IO-LC1
12/24VDC (power supply) 1 Loadcell / Strain gauge input. Voltage range: ±20mV, ±80mV, execution: AC/DC 1 Digital pnp input 2 setpoint pnp outputs (* Not supported by the M90 line). IO-LC3
12/24VDC (power supply) 3 Loadcell / Strain gauge inputs. Voltage range: ±20mV, ±80mV, execution: AC/DC 1 Digital pnp input 2 setpoint pnp outputs (* Not supported by the M90 line).
IO-D16A3-RO16
24VDC 16 Digital pnp/npn inputs, including 2 High-speed counters 3 Analog inputs, 10 bit, 0-20mA, 4-20mA 16 Relay outputs
3D View
IO-D16A3-TO16
24VDC 16 Digital pnp/npn inputs, including 1 High-speed counter 3 Analog inputs, 10 bit, 0-20mA, 4-20mA 16 Transistor pnp/npn outputs, including 1 High-speed output
3D ViewEX-D16A3-RO8
24VDC 16 Digital pnp/npn inputs, including 2 High-speed counters 3 Analog inputs, 10 bit, 0-20mA, 4-20mA 8 Relay outputs Adapter not required.EX-D16A3-TO16
24VDC 16 Digital pnp/npn inputs, including 1 High-speed counter 3 Analog inputs, 10 bit, 0-20mA, 4-20mA 16 Transistor pnp/npn outputs, including 1 High-speed output Adapter not required.IO-DI8-TO824VDC 8 Digital pnp/npn inputs, including 1 High-speed counter 8 Transistor pnp outputs. Supports Fast-response (in conjunction with Vision PLCs) IO-DI8-RO8
24VDC 8 Digital pnp/npn inputs, including 1 High-speed counter 8 Relay outputs. IO-DI8-RO424VDC 8 Digital pnp/npn inputs, including 1 High-speed counter 4 Relay outputs. IO-DI16
24VDC 16 Digital pnp/npn inputs, including 1 High-speed counter. IO-TO16
12/24VDC 16 Transistor pnp outputs. IO-RO8
24VDC (power supply) 8 Relay outputs. IO-RO16
24VDC (power supply) 16 Relay outputs. EX90-DI8-RO8
24VDC 8 Digital pnp inputs, including 1 High-speed counter 8 Relay outputs (This unit is housed in an open casing. Only one EX90 can be connected per PLC, as a single expansion module; EX-A1 adapter not required). IO-DI8-TO8-L
8 Digital pnp/npn inputs, including 1 High-speed counter 8 Transistor pnp outputs. IO-DI8-RO8-L
12VDC 8 Digital pnp/npn inputs, including 1 High-speed counter 8 Relay outputs. IO-DI8-RO4-L
12VDC 8 Digital pnp/npn inputs, including 1 High-speed counter 4 Relay outputs. IO-RO8-L
12VDC (power supply) 8 Relay outputs. IO-RO16-L
12VDC (power supply) 16 Relay outputs. IO-DI8ACH110/220 VAC 8 AC Inputs IO-AI8
I/O Expansion Module with 8 analog inputs 0÷10V/0÷20mA 14 bit   |
Communication Modules
An additional COM module can be installed in any Vision530™ unit.
V200-19-ET1
1 Ethernet port
V200-19-RS4
1 RS232/RS485 port
V200-19-RS4X1 RS232/RS485 port (Isolated)
 |
Special Features Flexible PID
Up to 12 built-in PID loops, including internal auto-tune, ramp-soak programmer and bumpless transfer. Use Vision’s PID loops to economically and efficiently combine accurate process control with the flexibility of a PLC  Data Tables Use Vision’s smart data tables (120K RAM and 192K Flash memory), to log dynamic data and store production recipes. Shaft-encoder InputsUse the controller’s integral 10kHz inputs as high-speed counters, frequency measurers, or to directly connect to shaft-encoders. PWM OutputsControl stepper motors or PID-based applications, via PWM, with the Vision120''''s onboard PWM outputs (model-dependent). Easy Scrolling between Recipes
Simply scroll between pre-programmed recipes or menus, using the panel’s arrow keys. This enables you to choose and activate a desired task via the HMI - immediately, on-site.  Image LibraryEasily design your graphic displays using the Vision’s extensive image library. Temperature & Weight measurementOnboard direct temperature inputs (PT100 or Thermocouple) give you the ability to control temperature-based applications, Loadcell I/O Expansion Modules enable you to hook up weight/strain inputs and achieve accurate measurements—no additional hardware required. (M91 series only, features are model-dependant) Time-based Control
Do you need a specific task to be performed at a specific time and date? Simply mark the hour, date or weekday in the PLC software—and you have created time-based control in 3 clicks.  Information Mode
Press the key on the operator panel to enter the PLC’s Information Mode, providing you with powerful diagnostic capabilities.  Virtual KeyboardApplication requires data entry? The Vision''''s virtual keyboard pops up automatically. |
Communication
EthernetGPRSGSM/SMSRemote AccessMODBUS CANbusOPC/DDE ServerAdditional Communication ProtocolsDataXport (to Excel)
Ethernet via TCP/IP
Use your factory’s existing LAN wiring to implement stable, high-speed control. Ethernet, the universal COM standard is embedded in Vision controllers. Ethernet enables MODBUS or open protocol commands to run over TCP/IP. Via the Ethernet port (purchased separately) and easy-to-use Ladder function blocks, Vision can:
- Exchange data, PLC to PLC
- Access external slave devices that support TCP/IP
- Use MODBUS IP or OPC to implement PC access via SCADA
- Acquire data from remote Vision units, networked into Intranets, Internets and wireless LANs
- Boost your connectivity by using dedicated IP address—and access/program remote Vision PLCs via the Internet
GPRS
Use GPRS wireless data transmission services to access your Vision PLC via the Internet. Vision can transmit IP packets of data to a remote PC connected to the Internet via GPRS modem, using a dedicated IP. GPRS enables you to operate remote PLCs on-line, upload, download, debug programs, and log application data—no wires required. GSM/SMS Use your cellular phone to implement real-time remote control in your application. Vision PLCs can send and receive SMS messages to/from any GPRS/GSM/CDMA cellular phone. The SMS-enabled controllers can:
Send & receive text and variable SMS messages
Route different messages to different phone numbers
Auto-acknowledge received messages
Answer data requests from your cell phone, directly to your cell phone
Remote Access
Use your PC to access remote PLCs via network connections, Ethernet, cellular (GPRS/GSM/CDMA) or landline modems. Unitronics’ unique Remote Access utilities enable you to remotely:
- Run, reset, or initialize a controller
- Download, upload, or debug PLC programs
- Read, write, and store online operand and system values
MODBUS
Use serial or TCP/IP MODBUS to create a multi-device network, and establish master-slave communication between Unitronics PLCs and any connected device that supports the MODBUS protocol (SCADA systems, servos and other peripheral devices). Any Unitronics controller in the network may function as either master or slave.
CANbus
CANopen: communicate with remote devices, ranging from simple, fast I/O-related devices such as encoders, to complex frequency converters. Compliant with CiA DS 301. UniCAN: use Unitronics'''' protocol to integrate up to 60 units into a high-speed network, and to transfer up to 512 MI register values during a single program scan.
CAN Layer 2 OPC/DDE Server
Unitronics’ OPC/DDE servers enable the PLC to exchange data with external applications. Use it to interface with SCADA systems, or to read/write PLC data from/to Excel, Access, or other Windows-based applications.
OPC/DDE Server software utilities are free downloads.
Additional Communication Protocols
The “Protocols” function block enables the Vision PLC to communicate, via RS232 and RS485, with a broad variety of external devices, such as bar-code readers and servos.
DataXport (to Excel)
A powerful software utility that captures PLC application data and exports it to Excel files for logging or processing. Data is exported, either directly, via network connection, or via modem, according to a user-defined schedule, or is pulled manually to view current status. |
|