Measuring gas name and range:
Sensor model | Gas name | Range (ppm) | Sensor model | Gas name | Range (ppm) |
GS-100DX | Cl2 | 0-1.5 | GS-1551DY | H2 | 0-4000 |
GS-260DY | H2S | 0-30 | GS-1680DY | CH3COOH | 0-30 |
GS-360DY | HCN | 0-30 | GS-1750DY | NO2 | 0-9 |
GS-480DY | HCl | 0-6 | GS-2460DY | NH3 | 0-75 |
GS-780DY | HF | 0-9 | GS-2460DY | Amine | 0-75 |
GS-900DX | Br2, I 2 | 0-3 | GS-3480DY | Chloride | 0-6 |
GS-1401DX | F2 | 0-3 | GS-3780DY | Fluoride | 0-9 |
![[Fixed type] Toxic Gas Detectors](http://www.bionics-japan.co.jp/en/gas/product/images/ttl_01.gif)

TX-FH
- 2 wire transmitter
- Analog display
- Using remote type sensor
- With digital display (FH-D)
- Without display (FH-N)


TX-FMD
- 2 wire transmitter
- Digital Display
- Using GS-DX/DY type sensor
- With analog display (FM)
- Without display (FN)


TX-DP-A
- 2 wire transmitter
- Analog display
- Using GS-DP type plug in sensor
- With digital display (DP-D)
- Without display (DP-N)


TX-EP-A
- 2 wire transmitter
- Analog display
- Using GS-EP type plug in sensor
- With digital display (EP-D)
- Without display (EP-N)


STX-PA
- Smart type
- LCD display (Gas name & concentration)
- Local visual alarm
- Alarm relay contacts SPDT x 2
- Alarm relay contact SPDT x 1
- Remote type sensor


STX-PA-NRD
- Smart type
- LCD display (Gas name & concentration)
- Local visual alarm
- Alarm relay contacts SPDT x 2
- Alarm relay contact SPDT x 1
- Non-remote type GS-DP sensor


STX-PA-NRE
- Smart type
- LCD display (Gas name & concentration)
- Local visual alarm
- Alarm relay contacts SPDT x 2
- Alarm relay contact SPDT x 1
- Non-remote type GS-EP sensor


TX-RS
- Smart type
- LCD display (Gas name & concentration)
- Local visual alarm
- Modbus output
- Alarm relay contacts SPDT x 2
- Alarm relay contact SPDT x 1
- Both available for Remote and Non-remote type sensor

TX-3350ExP-E-D For GS-DP sensor
- 2 wire transmitter
- Digital display
- Using GS-DP type plug in sensor
- Ex-proof type


TX-3350ExP-E-D For GS-EP sensor
- 2 wire transmitter
- Digital display
- Using GS-EP type plug in sensor
- Ex-proof type


SH-1000HT-D
- LED Display
- Built in system status function
- Same compact size for NF3, PFC detecting
- DC24V Operation
- Using GS-HT-J/ET-J sensor
- - Both on & off site calibration
- Optionally available following models
- With replay SH-1000HT-R


SH-1000GT
- Analog display
- Built in system status function
- Same compact size for NF3, PFC detecting
- DC24V Operation
- Using GT-H/E sensor
- - Both on & off site calibration


SH-1400TW-FL
- Analog display
- Same compact size for NF3, PFC detecting
- DC24V Operation
- Using GS-HX/HY/EP sensor


SH-1000PA
- Stand-Alone Gas detection system
- LCD display (Gas name & concentration)
- DC 4-20 mA output
- Local audio & visual alarm
- Alarm & error relay contacts
- AC 100-240V operation
- Using By-pass flow - Quick detecting System status
- Disconnect sensor
- Low electrolyte level of sensor
- Lose of sample flow
- Filament failure
- Using GS-HY/EP sensor


SH-1007EXW-GT
- Digital display
- DC24V Operation
- Using GS-HX/HY/EP sensor
- Ex-proof type


SH-4600IR
- N2O 0-300 ppm (Alarm point 50ppm)
- LCD display
- Local audio/visual alarm
- Alarm and error relay contacts
- Wall mount type
- AC100-240V operation


SH-4700IR
- CF4 0-500 ppm (Alarm point 100ppm)
- LCD display
- Local audio/visual alarm
- Alarm and error relay contacts
- Wall mount type
- AC100-240V operation


SH-4500IR
- SF6 0-1000 ppm (Alarm point 200ppm)
- LCD display
- Local audio/visual alarm
- Alarm and error relay contacts
- Wall mount type
- AC100-240V operation


TG-XTM-A
- When sensor is changed, it is automatically changed target gas, range, alarm level.
- Using GS-HS/ES sensor
- LCD display
- Local visual alarm
- Alarm and error relay contacts
- Panel mount type
- AC100-240V operation


TG-TEB
- When sensor is changed, it is automatically changed target gas, range, alarm level.
- Using GS-HS/ES sensor
- LCD display
- Local visual alarm
- Alarm and error relay contacts
- AC100-240V operation


MiniBA
- When sensor is changed, it is automatically changed target gas, range, alarm level.
- Using GS-HS/ES sensor
- LCD display
- Local visual alarm
- Alarm and error relay contacts
- AC100-240V and rechargeable battery operation


TG-4600TEB-IR
- N2O 0-300 ppm (Alarm point 50ppm)
- LCD display
- Local visual alarm
- Alarm and error relay contacts
- AC100-240V operation


TG-4700TEB-IR
- CF4 0-500 ppm (Alarm point 100ppm)
- LCD display
- Local visual alarm
- Alarm and error relay contacts
- AC100-240V operation


TG-4500TEB-IR
- SF6 0-1000 ppm (Alarm point 200ppm)
- LCD display
- Local visual alarm
- Alarm and error relay contacts
- AC100-240V operation


TG-2100TEB-IR
- IPA 0-2% monitor
- LCD display
- Local visual alarm
- Alarm and error relay contacts
- DC24V operation