Measurement Cell


Transducer

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Output signal: mV
  • Materials: Stainless steel, Titanium, Hastelloy







Polynom Transducer

 


  • Pressure measuring range: 2 bar…100 bar
  • Total Error: ≤ ± 0.2 % rdg (30…100 %FS)
  • Compensation: -40…60 °C
  • Operating temperature: -40…150 °C
  • Output signal: mV
  • Materials: Stainless steel







Pressure and Temperature Transmitters


ATM.1ST/T

 


  • Pressure measuring range: 100 mbar…25 bar
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -50…150 °C
  • Operating temperature: -40…125 °C
  • Process temperature: -50…150 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel







ATM.1ST

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.10 / 0.05 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: 0…5 / 0…10 V DC, 4…20 mA
  • Total Error Band: ≤ ± 0.30 %FS (0…70 °C)
  • Materials: Stainless steel, Titanium







ATM.1ST/Ex

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.10 / 0.05 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: 4…20 mA
  • Total Error Band: ≤ ± 0.30 %FS (0…70 °C)
  • Materials: Stainless steel, Titanium







ATM.ECO

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: 0…5 / 0…10 V DC, 4…20 mA
  • Total Error Band: ≤ ± 0.70 %FS (0…70 °C)
  • Materials: Stainless steel, Titanium







ATM.ECO/Ex

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: 4…20 mA
  • Total Error Band: ≤ ± 0.70 %FS (0…70 °C)
  • Materials: Stainless steel, Titanium







ATM

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Output signal: 0…5 / 0…10 V DC, 0…20 / 4…20 mA
  • Materials: Stainless steel, Titanium







ATM/Ex

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium







ATM/F

 


  • Pressure measuring range: 100 mbar…25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -25…100 °C
  • Output signal: 0…5 / 0…10 V DC, 0…20 / 4…20 mA
  • Materials: Stainless steel







ATM/F/Ex

 


  • Pressure measuring range: 100 mbar…25 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -25…100 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel







ATM/GR

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Two potential free switches (48 V, 2 A, 60W)
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Materials: Stainless steel, Titanium
  • Feature: Output signal 0…20 mA / 4…20 mA







ATM/K

 


  • Pressure measuring range: 100 mbar…25 bar
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…125 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel







ATM/T

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Temperature measuring range: -50…150 °C
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • 2 Output signals (p & T): 0…10 V DC, 0…20 / 4…20 mA
  • Materials: Stainless steel, Titanium







DTM

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Interface: RS232, RS485
  • Materials: Stainless steel, Titanium







PTM

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Adjustable: 1:4 of the nominal range within -5% to +105%
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible







PTM/Ex

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Adjustable 1:4 of the nominal range within -5% to +105%
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible







PTM/RS485

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Adjustable 1:4 of the nominal range within -5% to +105% (analog output)
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -25…85 °C
  • Operating temperature: -25…85 °C
  • Process temperature: -40…150 °C
  • 2 Output signals (p & T): 4…20 mA
  • Interface: RS485 (Modbus RTU)
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible







TM

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: mV
  • Materials: Stainless steel, Titanium







TM/Ex

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Operating temperature: -40…125 °C
  • Process temperature: -40…150 °C
  • Output signal: mV
  • Materials: Stainless steel, Titanium







TS 100

 


  • Temperature measuring range: -50…150 °C
  • Operating temperature: -25…85 °C
  • Process temperature: -50…150 °C
  • Output signal: 0…5 / 0…10 V DC, 0…20 / 4…20 mA
  • Materials: Stainless steel
  • Feature: 850 bar proof pressure







 







Submersible level and temperature transmitters


ATM.1ST/N/T

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -5…80 °C
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium







ATM.1ST/N

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.10 % FS
  • Total Error Band: ≤ ± 0.30 %FS (-5…50 °C)
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 0…5 / 0…10 V DC, 4…20 mA
  • Materials: Stainless steel, Titanium







ATM.1ST/N/Ex

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.10 % FS
  • Total Error Band: ≤ ± 0.30 %FS (-5…50 °C)
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium







ATM.ECO/N

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 % FS
  • Total Error Band: ≤ ± 0.70 %FS (-5…50 °C)
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 0…5 / 0…10 V DC, 4…20 mA
  • Materials: Stainless steel, Titanium







ATM.ECO/N/Ex

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 % FS
  • Total Error Band: ≤ ± 0.70 %FS (-5…50 °C)
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium







ATM/N

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 0…5 / 0…10 V DC, 0…20 / 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Optional surge (lightning) protection







ATM/N/Ex

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Optional surge (lightning) protection







ATM/N/T

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Temperature measuring range: -5…80 °C
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • 2 Output signals (p & T): 0…10 V DC, 0…20 / 4…20 mA
  • Materials: Stainless steel, Titanium







ATM/N 19

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 / 0.10 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 0…5 / 0…10 V DC, 4…20 mA
  • Materials: Stainless steel
  • Feature: 19 mm diameter







ATM/K/N

 


  • Pressure measuring range: 1…200 mH2O
  • Accuracy: ≤ ± 0.25 % FS
  • Operating temperature: -5…50 °C
  • Process temperature: -5…50 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel
  • Feature: Optional surge (lightning) protection







ATM/NC

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 2.0 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 0…5 / 0…10 V DC, 0…20 / 4…20 mA
  • Materials: PVDF
  • Feature: Optional surge (lightning) protection







ATM/NC/Ex

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 2.0 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: PVDF
  • Feature: Optional surge (lightning) protection







DTM/N

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Interface: RS232, RS485
  • Materials: Stainless steel, Titanium







PTM/N

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Adjustable 1:4 of the nominal range within -5% to +105%
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible







PTM/N/Ex

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Adjustable 1:4 of the nominal range within -5% to +105%
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: 4…20 mA
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible







PTM/N/RS485

 


  • Pressure measuring range: 1…250 mH2O
  • Adjustable 1:4 of the nominal range within -5% to +105% (analog output)
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -25…85 °C
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • 2 Output signals (p & T): 4…20 mA
  • Interface: RS485 (Modbus RTU)
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration with software possible, optional surge (lightning) protection







PTM/N/SDI-12

 


  • Pressure measuring range: 5…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Temperature measuring range: -25…85 °C
  • Operating temperature: -5…50 °C
  • Process temperature: -5…50 °C
  • Interface: SDI-12 (V1.3)
  • Materials: Stainless steel, Titanium
  • Feature: Recalibration possible, Adjustable units







MTM/N 10

 


  • Pressure measuring range: 10…100 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25
  • Operating temperature: -5…50 °C
  • Process temperature: -5…50 °C
  • Output signal: mV
  • Materials: Stainless steel, Titanium
  • Feature: Level transmitter with 10 mm diameter, Versions with ATM/N or DL/N 70 possible







TM/N

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: mV
  • Materials: Stainless steel, Titanium







TM/N/Ex

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.50 / 0.25 % FS
  • Operating temperature: -5…80 °C
  • Process temperature: -5…80 °C
  • Output signal: mV
  • Materials: Stainless steel, Titanium








Data Loggers / Communication


DL

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -40…85 °C
  • Process temperature: -40…100 °C
  • Interface: RS232
  • Materials: Aluminium (Housing), Stainless steel
  • Feature: Battery operation, Measurement interval 2s…24h, 130''000 Measurement values







DL/N

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -40…85 °C
  • Process temperature: -5…80 °C
  • Interface: RS232
  • Materials: Aluminium (Housing), Stainless steel
  • Feature: Battery operation, Measurement interval 2s…24h, 130''000 Measurement values







DL/Ex

 


  • Pressure measuring range: 100 mbar…1000 bar
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -40…85 °C
  • Process temperature: -40…100 °C
  • Interface: RS232
  • Materials: Aluminium (Housing), Stainless steel
  • Feature: Battery operation, Measurement interval 2s…24h, 130''000 Measurement values







DL/N/Ex

 


  • Pressure measuring range: 1…250 mH2O
  • Accuracy: ≤ ± 0.25 / 0.10 % FS
  • Operating temperature: -40…85 °C
  • Process temperature: -5…80 °C
  • Interface: RS232
  • Materials: Aluminium (Housing), Stainless steel
  • Feature: Battery operation, Measurement interval 2s…24h, 130''000 Measurement values