P21149 | P21150 | P21144 | Kgft 125 Ex | Kgft 150 Ex | Kk 030 Ex | Ege-Elektronik | Cảm Biến Đo Mức Ege | Level Sensor Ege | Ege Vietnam

Liên hệ

D5 Miếu Nổi, Đinh Tiên Hoàng, P.3, Q.bình Thạnh


P21149  KGFT 125 Ex

P21149 | P21150 | P21144 | KGFT 125 Ex | KGFT 150 Ex | KK 030 Ex

Level Sensors ex-sensor zone 0 G1/4
Data sheet Data sheet KGFT 125 Ex  

 


Level controllers - Applications

Microwave meter MFM
The MFM level meters for continuous monitoring of various liquids allow for an exact determination of the fill level in plastic or metal tanks of any size. With a maximum tolerance of 3 mm the devices offer the highest measurement precision. The level sensors work with numerous liquids such as water, oil or emulsions. To this end microwaves are “guided” in the measuring rod – and are reflected at the surface of the medium, and the sensor determines the fill level. No adjustment for various media is necessary. The aluminium and AISI 316 Ti stainless steel MFM probes are suitable for ambient temperatures between -20 and +70 °C. They are available in optional sizes between 500 and 2000 mm in length. The sensors are equipped with a G3/4 thread and are connected via an M12 plug. The fill level is transmitted to the analysis unit or SPS by means of a 4...20 mA signal.

Microwave level controllers
The microwave level controllers of the MFC and MFK series respond to media contact at the tip of the sensor.
The devices of the MFK series are made of stainless steel and PTFE and are equipped with a G1/2 process connection. The sensors have a length of 40 mm. Thanks to their integrated electronics, no downstream amplifier is required. The sensors do not have to be adjusted to different media, and for containers made of plastic material, no earth connection is required.
Users can adjust the sensitivity of the devices of the MFC series using a pushbutton. Thus, the sensors can distinguish between different layers of liquids (e.g. water and oil) in the containers allowing for an easy separation of liquids. The stainless steel and PTFE microwave sensors can be used for virtually all container types and sensor environments. They are also suited for use with powder granulates. The sensors are available with a length of between 120 mm and 1000 mm thus offering various different installation options.

Capacitive sensors
The operation of these level sensors is based on a dielectric measuring method. All media which are surround the sensors measuring electrode, built into the tip of the probe, change the state of dielectric balance between the measuring electrode and the surrounding space. This disturbance in the balance triggers a switching command inside the device. The balance can be adjusted with a built-in potentiometer so that materials with different bulk densities and corrospondingly different dielectric constants can be measured optimally. Metallic or metal clad vessels should be earthed. In the case of plastic vessels filled with electrically conductive materials, the latter should be earthed. In the case of plastic vessels filled with non-conducting materials, an earthed metal band applied on the outside of the vessel may be used as a counter-electrode.

Medium adjustment for capacitive sensors
Level sensors are set in such a way that they switch upon contact with a medium. The medium adjustment should, if possible, take place without removal under operating conditions. If the built-in part of the sensor can be completely submerged or covered during operation, the adjustment must also take place in this state. If only medium contact is possible, the adjustment takes place upon contact. The trimmer potentiometer is protected by a plastic bolt. This bolt must be removed before the desired sensitivity is set. Turning it clockwise increases the response sensitivity. The adjustment potentiometer is turned until the switch output switches through (normally-open contact). You achieve switching point safety by continuing to turn the potentiometer half a turn to one turn. Devices with a LED line are adjusted to two green LEDs. If the medium adjustment has taken place, the plastic bolt must be fixed again.

Electrically conductive media are difficult to monitor using capacitive level controllers. For this task, a microwave compact device (Series MFC) is considerably better suited.

Laboratory adjustment
lf adjustment cannot be carried out with the sensor mounted in operating position, it can be performed upon a similar vessel. It must, however, be made sure that this vessel is set upon an earthed metal plate, or that the liquid within the vessel is earthed by means of an introduced wire. The minium heigh an minimum diameter of the experimental vessel should be about 10 cm.
lf setting is correct, the filling level monitor reacts correctly if 50% of the electrode diameter is covered. When mounted vertically, sensors reacts upon contact with the medium. Reaction time lag is less than 0.25 sec.

Opto-sensors UF.../UR...
Optical sensors react to a change of the refraction index within the proximity of the sensor tip when being immersed into fluid. The sensor does not have to be adjusted. In rare cases, the container wall or particles within the fluid may reflect the light emitted by the sensor and thus interfere with the fluid detection. A trial run is recommended in such instances. The sensors are designed to be used with the respectively listed fluids under normal conditions. The chemical compatibility and technical suitability of the sensor should be tested when used with unlisted fluids.

Chemical resistance level controller

Thermal level controllers for hazardous areas
EGE provides the TFKS and TFGS series of thermal level controllers for explosive gas atmospheres (zone 0 and 1). The sensors are suitable for stationary and mobile use, e.g. in gasoline or diesel tank trucks. Featuring a G3/4 thread, the devices are available with a maximum length of 400 mm or with a fixed immersion depth. They are connected to SF3 amplifier units. Both sensor types have a nominal resistance of 160 W. Manufactured from aluminum or stainless steel 1.4571, TFKS and TFGS sensors provide IP 68 protection and are suitable for ambient temperatures between -20 and +80 °C. They are connected via M12 plugs.

Sensors for explosion hazardous areas
Fill level monitors for use in zone 0 or zone 20 are operated with the associated amplifiers listed in the respective connection chart. The analysis devices are always operated outside of the Ex area. Sensors of the series KGFT...Ex are used in conjunction with an intermediate amplifier, which is approved for installation in zone 1. Optical Ex sensors URFG-Ex can also be driven with the amplifier SF3 for application in zone 1.

Ege-elektronik Vietnam - Pitesco Vietnam đại lý phân phối thiết bị hãng ege-elektronik tại Vietnam.

Vui lòng Liên hễ để được tư vấn và hỗ trợ giá tốt nhất.

Trần Văn Ý ( Mr )

[Sales Department]

Cellphone :  +84 989 199 111 | +84 0916  152  811

Emaill  : vany.pitesco@gmail.com
Yahoo  :     vany.pitesco  
Sky       :    ytranht                           

Văn phòng Đồng Nai

261 tổ 19,QL 51, Kp 1, P Long Bình Tân, Tp Biên Hòa, Đồng Nai

Pitesco Vietnam JSC.,

Add: D5 Mieu Noi Resident, Dinh Tien Hoang St, W.3, Binh Thanh

Dist, HCM City, Viet Nam


Bình luận

HẾT HẠN

0989 199 111
Mã số : 8107583
Địa điểm : Đồng Nai
Hình thức : Cần bán
Tình trạng : Hàng mới
Hết hạn : 02/08/2020
Loại tin :

Thường

Để mua hàng an toàn trên Rao vặt, quý khách vui lòng không thực hiện thanh toán trước cho người đăng tin!

Gợi ý cho bạn